Home > Products > Transmitter > OPT-564

Transmitter

Transmitter for optical transmission method torque meter OPT-564

OPT-564
Feature
Special transmitter for optical transformer method torque meter.
The calibration data for four torque meters can be recorded and changed.
Digital compensation of asymmetry, linearize and twist direction reversing can be executed.
Up to 2 points as analog output for torque is selectable from a voltage output (standard), current output or frequency output.
The analog output for the rotational speed is selected from either of voltage output or current output, and are selected whether or not to exist of the frequency output.
Digital output is selectable one from RS-232C interface, RS-422/485 interface, Profibus interface or CANopen interface.
Specifications
Roter supply voltage 24 VDC }2 VDC, 2 A
Input signal / Torque Frequency input 5 kHz ~ 15 kHz (at F-54=0)
Frequency input 120 kHz ~ 360 kHz (at F-54=1)
Input signal
/ Rotation speed
Frequency input 0 kHz ~ 50 kHz (at 120 teeth)
Frequency input 0 kHz ~ 100 kHz (at 240 teeth)
Frequency input 0 kHz ~ 150 kHz (at 360 teeth)
Output signal /
Analog output (Standard)
±10 VDC (at [negative rated torque] ~ [positive rated torque])
Load resistance : 2 kΩ or more
Output capacitance load : 0.1 μF or less
(Select at the time of order) Current output and frequency output for torque
Voltage output, Current output, and Frequency output for rotation speed
A/Z effective range }10 %R.O.
Digital compensation Asymmetry compensation }10R.O.
Linearize compensation Up to 10 points
(5 points for 0 to positive rated output. 5 points for 0 to negative rated output)
Torsion direction reversal
Reverses torsion direction and output signal.
(Standard is positive output for counterclockwise direction.)
Non-linearity 0.01 %F.S. (Display and voltage output)
0.05 %F.S. (Current output)
CHECK Approx. 80 % of rated output (Set by default function)
Frequency response range DC ~ 6 kHz (when F54 = 1)
Changeable to 1 Hz, 10 Hz, 30 Hz, 50 Hz, 100 Hz, 300 Hz, 500 Hz, 1 kHz, and 6 kHz
DC ~ 1 kHz (when F54 = 0)
Changeable to 1 Hz, 10 Hz, 30 Hz, 50 Hz, 100 Hz, 300 Hz, 500 Hz, and 1 kHz
Above is 10 Hz ~ 6 kHz : -3 dB±1 dB, 1 Hz : -3 dB±3 dB
Torque analog output delay time 270 μs (Typ.),
when 6 kHz of low pass filter and 1 time of moving average samples.
Rotation speed analog output delay time 24 ms (Typ.)
when 10 Hz of low pass filter and 1 time of moving average samples.
Sampling rate Torque : 60 000 times/s (when F-54 = 1)
Torque : 10 000 times/s (when F-54 = 0)
Rotation speed : 10 000 times/s
Torque display section Output display : 0 ~ ±99 999 digital display (Green LED)
Display format : Analog voltage / Torque
Decimal point display : Changeable to No display, 101, 102, 103 and 104
Condition display : A/Z, LOCK, CHECK, H, M, ERROR
Unit display : Changeable to V, Nm and kNm
Display frequency : Approx. 20 cycles/s (Changeable to 4 cycles/s)
Calibration number : 1 to 4 (display the selected calibration number.)
Rotation display section Output display : 0 ~ ±27 500 digital display (green LED)
Out-of-range display : [-OS] appears for minus overflow, [OS] appears for plus overflow.
Display format : Rotation speed
Unit display : r/min
Display frequency : Approx. 20 cycles/s (Changeable to 4 cycles/s)
Various function Digital filter, Sheet key lock, Changeover of calibration data,
Indication of luminous energy decreaset, Error code display
Operating temp./humidity range 0 ~ 50 , 85 %RH or less (Non condensing)
Power supply Power supply voltage
100 VAC ~ 240 VAC (Permisible variable range : 85 VAC ~ 264 VAC),
Power consumption Approx. 60 VA (at 100 VAC)
Outline dimensions
(W x H x D)
68 mm x 209 mm x 252 mm (Excludes protruding parts)
Weight Approx. 2 kg
Options
Current output, Frequency output, RS-232C interface, RS-422/485 interface, PROFIBUS interface, CANopen interface, Rotation detector MP-982
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
OPT-564.zip (545KB) No.EN351564 (469KB) ---
EDS file (for the set of CANopen object)
OPT-564_EDS.eds (16KB)
GSD file (for the set of PROFIBUS interface)
MIMI1181.gsd (4KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.