Home > Products > Transmitter > OPT-563B

Transmitter

Transmitter for optical transmission method torque meter OPT-563B

OPT-563B
Feature
¡ Special transmitter for optical transformer method torque meter.
¡ The calibration data for four torque meters can be recorded and changed.
¡ Digital compensation of asymmetry, linearize and twist direction reversing can be executed.
¡ Up to 2 points as analog output for torque is selectable from a voltage output (standard), current output or frequency output.
¡ The analog output for the rotational speed is selected from either of voltage output or current output, and are selected whether or not to exist of the frequency output.
¡ Digital output is selectable one from RS-232C interface, RS-422/485 interface, Profibus interface or CANopen interface.
Specifications
Roter supply voltage DC24 V }2 V, 2 A
Input signal Torque signal 5 kHz ~ 15 kHz (based on signal RS-485)
Rotation speed signal 0 Hz ~ 50 000 Hz
Output signal Analog output (Standard)
DC}10 V (at } rated output of torque transducer)
Digital output (Option)
Select one from RS-232C, RS-422/485 , PROFIBUS or CANopen.
Zero adjustment range }2 %R.O.
Digital compensation Asymmetry compensation }10“R.O.
Linearize compensation 10 points at the maximum
Twist direction reversing compensation
The direction of the twist and the output signal are reversed.
Non-linearity 0.01 %F.S. (Voltage output)
CHECK Approx. 80 % of rated output (Set by function)
Frequency response range (Changeable to 1 Hz, 10 Hz, 30 Hz, 50 Hz, 100 Hz, 300 Hz, 500 Hz
or 1 kHz)
Above is 10 Hz ~ 1 kHz : -3 dB}1 dB, 1 Hz : -3 dB}3 dB
Torque display section Dsiplay of output 0 ~ } 99 999 digital display (Green LED)
Display type Analog output, Torque
Condition display A/Z, LOCK, CHECK, H, M, ERROR
Display of unit Changeable to V, Nm or kNm
Display rate Approx. 20 times/s (Changeable to 4 times/s)
Rotation speed display section Display of output 0 ~ } 27 500 digital display (Green LED)
Display type Rotation speed
Condition display LOCK
Display of unit r/min
Display rate Approx. 20 times/s (Changeable to 4 times/s)
External control input signal A/Z, A/Z off, LOCK,
External control output signal ERROR
Various function Digital filter, Sheet key lock, Changeover of calibration data,
Indication of luminous energy decrease.
Operating temp./humidity range 0 Ž ~ 50 Ž, 85 %RH or less (Non condensing)
Power supply Power supply voltage
AC100 V ~ AC240 V (Permisible variable range : AC85 V ~ AC264 V),
Power consumption Approx. 60 VA (at AC100 V)
Outline dimensions
(W x H x D)
68 mm x 209 mm x 252 mm (Excludes protruding parts)
Weight Approx. 2 kg
Options
Current output, Frequency output, RS-232C interface, RS-422/485 interface, PROFIBUS interface, CANopen interface, Rotation detector MP-982
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
OPT-563B.zip (999KB) No.351563B-D (140KB) No.294-1596-F (1,402KB)
Simple instruction
No.EN294-1723-B (705KB)
<in Chinese>
No.CN294-1723-A (1,043KB)
for PROFIBUS
No.EN294-1633-B (165KB)
for CANOpen
No.EN294-1634-C (167KB)
EDS file (for the set of CANopen object)
OPT-563B_EDS.eds (16KB)
GSD file (for the set of PROFIBUS interface)
NMB_0F46.gsd (4KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.