}10 V output
(}0.5 mV/V input, at bridge power supply AC2.0 V
rms)
Output Load Resistance
Resistance load 2
k or more
Output capacity load 0.1 uF or less
Zero adjustment range
}2.5 mV/V
Coarse adjustment Automatic balance
Fine adjustment Zero adjustment trimmer
Resistance section pprox.1 %(}2.5 mV/V)
Capacitance section@Up to 2 000 pF is possible
Automatic balancing time Approx.1 sC
Accuracy@}0.2 %F.S.C
Back-up time : 24 h or more
Non-linearity
0.05 %F.S.
Temperature efficient
Zero point }0.1 V/ (Input
conversion)
Sensitivity within }0.05 %F.S./
Frequency response
range
DC to 2 kHz(Filter
: W/B)
(Changeable to 1 Hz, 10 Hz, 100 Hz, 300 Hz, 1 kHz
or W/B)
10 Hz to W/B:{1 dB -3 dB}1 dB,
1 Hz:{1 dB -3 dB}3 dB
Display section
Output voltage display
0 to }10.000 Digital display (Green LED)
Sampling rate
Approx. 4 times/s
ERROR function
(+10 V or more or
-10 V or less), the display flashes 0.000 or -0.000
on and off and also ERROR will be shown. (Photocoupler
output)
Remote function
Automatic balance
}CALIB
LOCK function
Automatic balance
Prohibit the operation of } CALIB
(Including }CALIB of automatic balance for remote
function)
Operating temp./humidity range
Temperature -10
to 50
Humidity 85 %RH or less (Non condensing)
Power supply
Power supply voltage AC100 V}10 V
50/60 Hz
Power consumption Approx. 10 VA (at AC100 V)
Outline dimensions
(W x H x D)
42 mm x 176 mm x 284.4
mm (Excludes protruding parts.)
Adobe Acrobat Reader is required to refer the Specification data sheet.