PCB type Transmitter@CSA-504S*
Printed circuit board type
1 CH (CSA-504S-1B)
4 CH (CSA-504SB)
Bridge power supply
CSA-504S-1B : DC10 V}0.1 V
CSA-504SB : DC10 V}1 V
Sensitivity
10 V output at the input of 1 mV/V
Sensitivity adjustable range
1 000 times
Adjustable from 1/1 times to 0.9 times
Input range
0.3 mV/V to 3 mV/V
Output voltage
}10 V Load resistance 2 k-ohm or more
Zero adjustment range
Tare compensation
Adjustable by internal fixed resistance
Zero adjustment
Adjustable }0.1 mV/V by trimmer
Non-linearity
CSA-504S-1B : 0.05 %F.S.
CSA-504SB : }0.1 %F.S.
Temperature efficient
Zero point within }2 uV/ (Input conversion)
Sensitivity within }0.05 %F.S./
Frequency response range
10 Hz (}3 dB)
Operating temp./humidity range
Temperature 0 to 50 ,
Humidity 85%RH or less (Non condensing)
Power supply voltage
CSA-504S-1B : }DC15 V}0.75 V 150 mA
CSA-504SB : DC}15 V}0.75 V 550 mA
(When summing four transducers in all channels.)
Outline dimensions
(W x H x D)
CSA-504S-1B : 70 mm x 70 mm x 20 mm
CSA-504SB : 42 mm x 176 mm x 164.4 mm
(Excludes protruding parts.)
Weight
CSA-504S-1B : Approx. 0.2 kg
CSA-504SB : Approx. 0.3 kg
CAD files (DXF)
Specification sheet (PDF)
Instruction manual (PDF)
CSA-504SB (201KB)
CSA-504S-1B (51KB)
CSA-504SB
No.351504SB (47KB)
CSA-504S-1B
No.351504S-1B (18KB)
No.294-1012 (402KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.