Home > Products > Transmitter > CSA - 503C

Transmitter

Transmitter csa503c

CSA - 503C
Feature
  • E Built-in remote Sensing circuit
  • E Automatic zero function(Option)
  • E CALIB. is equipped normally.
  • ECHECK is equipped normally.
Specifications
Bridge power supply DC10 V}0.3 V within 120 mA (Changeable to DC2.5 V or DC5 V)
with remote sensing function
Input range 0.3 mV/V ~ 3 mV/V
Output Output }10 V
(}0.3 mV/V input at bridge power supply DC10 V)
Output Load Resistance 2 k-ohm or more
Zero adjustment range }2.4 mV/V
Non-linearity 0.01 %F.S.
Temperature efficient Zero point within }0.45 ƒΚV/Ž (Input conversion)
Sensitivity within }0.005 %F.S./Ž
Frequency response range 10 Hz (Changeable to 1 Hz, 100 Hz)
Operating temp. / humidity range Temperature -10 Ž ~ 50 Ž
Humidity 80 %RH or less (Non condensing)
Power supply Power supply voltage AC100 V}10 V, 50/60 Hz,
Power consumption Approx. 10 VA (at AC100 V)
Outline dimensions (WxHxD) 42 mmx176 mmx164.4 mm (Excludes protruding parts)
Weight Approx. 1.5 kg
Options
Current output, Automatic zero function, Power supply voltage
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
csa503c (255KB) No.351503C (165KB) No.294-1041 (816KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.