Home > Products > Tiebar Gage Measurement System > Digital Peak Holder CSD-819C-S12

Tiebar Gage Measurement System

Digital Peak holder CSD-819C-S12

TSD - 591
Feature
  • ・ Suitable for the operation management of equipment that usese a tie bar.
  • ・ High speed sampling rate of 2000 times/s in the compact size and light weight unit.
  • ・ Various kind of peak mode setting.
  • ・ Installed the automatic calibration function to execute the span adjustment by automatic operation.
  • ・ [CE] mark applicable.
  • ・ Suitable for the press fitting measurement.
Specifications
Bridge power supply DC 10 V±0.5 V within 60 mA (Changeable to DC5 V or DC2.5 V)
Input range Full scale (F.S.) setting is available at the input from ±0.1 mV/V to ±3.1 mV/V. (When bridge power supply is DC10 V or DC5 V)
Full scale (F.S.) setting is available at the input from ±0.8 mV/V to ±3.1 mV/V. (When bridge power supply is DC2.5 V)
Output range DC±10 V, Load resistance 5 kΩ or more.
(F.S. is set by the function)
Output times 100 times/s, 500 times/s, 1 000 times/s or 2 000 times/s
(Synchronous with A/D sampling rate.)
Output resolution Same as the display resolution.
Zero adjustment range ±2.0 mV/V
Non?linearity Display 0.025 %F.S., Output 0.025 %F.S.
Temperature coefficient Zero point ±0.5 μV/℃
Sensitivity ±0.01 %F.S./℃
(Input conversion, in F.S. setting at the input from ±0.5 mV/V to 3.1 mV/V)
Input filter 10 Hz, 100 Hz or 1 kHz changeable.
A/D sampling rate 2 000 times/s
(100 times/s, 500 times/s or 1 000 times/s changeable.)
Load display  
Display range −11 000 to 11 000
Comparator display  
Display range −99 999 to 99 999
Number of display 1 point (select from S0, S1, S2, S3 or S4.)
Display rate 20 times/s(4 times/s, 50 times/s or 100 times/s changeable)
External control function ZERO, PEAK/TRACK, HOLD, RESET, SEL.1, SEL.2
Comparator function  
Set value −99 999 to 99 999
Numbers of setting 5 points(S0、S1、S2、S3、S4) ※S0 is set by function.
Display rate 20 times/s(4 times/s, 50 times/s or 100 times/s changeable)
Open collector output signal S1、S2、S3、S4 The open collector is ON when reached under/over the comparator set value.
S0 The open collector is ON with either condition by function setting.
Operating temp./humidity range

Temperature 0 ℃ ~ 50 ℃, Humidity 85 %RHor less(Non condensing)

Power supply voltage AC100 V to 240 V (Allowable variable range AC85 V to 264 V)
Power consumption Approx. 8 VA (Without option, at AC100 V)
Approx. 17 VA at max. (With options, at AC100 V to AC240 V)
Outline dimensions(WxHxD) 96 mm ×96 mm ×129.5 mm (Excludes protruding parts.)
Weight

Approx. 0.5 kg (Without any options.)

Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
CSD-819C (336KB) --- ---