Digital
Peak holder CSD-819C-S12 |
 |
 |
|
- ・ Suitable for the operation management of equipment that usese a tie bar.
- ・ High speed sampling rate of 2000 times/s in the compact size and light weight unit.
- ・ Various kind of peak mode setting.
- ・ Installed the automatic calibration function to execute the span adjustment by automatic operation.
- ・ [CE] mark applicable.
- ・ Suitable for the press fitting measurement.
|
|
 |
|
| Bridge power supply |
DC 10 V±0.5
V within 60 mA (Changeable to DC5 V or DC2.5 V) |
| Input range |
Full scale (F.S.) setting is available at the input from ±0.1 mV/V to ±3.1 mV/V.
(When bridge power supply is DC10 V or DC5 V)
Full scale (F.S.) setting is available at the input from ±0.8 mV/V to ±3.1 mV/V.
(When bridge power supply is DC2.5 V) |
| Output range |
DC±10 V, Load resistance 5 kΩ or more.
(F.S. is set by the function) |
| Output times |
100 times/s, 500 times/s, 1 000 times/s or 2 000 times/s
(Synchronous with A/D sampling rate.) |
| Output resolution |
Same as the display resolution. |
| Zero adjustment range |
±2.0 mV/V |
| Non?linearity |
Display 0.025 %F.S., Output 0.025 %F.S. |
| Temperature coefficient |
Zero point ±0.5 μV/℃
Sensitivity ±0.01 %F.S./℃
(Input conversion, in F.S. setting at the input from ±0.5 mV/V to 3.1 mV/V) |
| Input filter |
10 Hz, 100 Hz or 1 kHz changeable. |
| A/D sampling rate |
2 000 times/s
(100 times/s, 500 times/s or 1 000 times/s changeable.) |
| Load display |
|
| Display range |
−11 000 to 11 000 |
| Comparator display |
|
| Display range |
−99 999 to 99 999 |
| Number of display |
1 point (select from S0, S1, S2, S3 or S4.) |
| Display rate |
20 times/s(4 times/s, 50 times/s or 100 times/s changeable) |
| External control function |
ZERO, PEAK/TRACK, HOLD, RESET, SEL.1, SEL.2 |
| Comparator function |
|
| Set value |
−99 999 to 99 999 |
| Numbers of setting |
5 points(S0、S1、S2、S3、S4) ※S0 is set by function. |
| Display rate |
20 times/s(4 times/s, 50 times/s or 100 times/s changeable) |
| Open collector output signal |
S1、S2、S3、S4 The open collector is ON when reached under/over the comparator set value.
S0 The open collector is ON with either condition by function setting. |
| Operating temp./humidity range |
Temperature 0 ℃
~ 50 ℃, Humidity 85 %RHor less(Non condensing)
|
| Power supply voltage |
AC100 V to 240 V (Allowable variable range AC85 V to 264 V) |
| Power consumption |
Approx. 8 VA (Without option, at AC100 V)
Approx. 17 VA at max. (With options, at AC100 V to AC240 V) |
| Outline dimensions(WxHxD) |
96 mm ×96 mm ×129.5 mm (Excludes protruding parts.) |
| Weight |
Approx. 0.5 kg (Without any options.) |
|
 |
|
| CAD files (DXF) |
Specification sheet (PDF) |
Instruction manual (PDF) |
| CSD-819C
(336KB) |
--- |
--- |
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here. |
|
| |