Products Topics Contact us

Home > Products > Tiebar Gage Measurement System > CSA-591

Tiebar Gage Measurement System

Transmitter CSA-591

CSA - 591
Feature
  • E High response 1 kHz
  • EAuto zero functions (Optional)
Specifications
Bridge power supply DC8 V}0.3 V within 30 mA
Applicable transducer 1 unit of tie-bar gage(350 type 2 pieces a couple)
Input range }300 ST to }2 000 ST
Output voltage }10 V output
Output load resistance 2 k or more
Zero adjustment range Coarse adjustment Approx. }10 000 ST adjustable by 16 steps rotary switch.
Fine adjustment Approx. }3 000 ST adjustable by fine/coarse adjustment trimmer
Sensitivity adjustable range Coarse adjustment
Approx.}10 000 ST adjustable by 16 steps rotary switch.
Fine adjustment
Adjustable by trimmer
Non-linearity 0.1 %F.S.
Temperature efficient Zero }10 V/ (Input conversion) , Sensitivity }0.05 %F.S./
CALIB 300 ST}15 ST 1_
Frequency response range Approx. 100 Hz, orApprox. 30 Hz
Operating temp./humidity range

0 to 50 ,

80 %RH or less ((Non condensing)

Power supply voltage DC24 V (DC18 V to DC36V)
Power consumption Approx. 0.15A (at24 V)
Outline dimensions(WxHxD) 48 x 96 x 131 (mm) (excludes protruding parts)
Weight Approx. 0.5 kg
Options
Auto zero function
Download Terms and Conditions
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
CSA-591 (250KB) No.382591 (64KB) No.294-1141 (718KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.