Products Topics Contact us

Home > Products > Testing Machine > LTS-200N/LTS-500N

Testing Machine

Load testor LTS-200N/LTS-500N

LTS-200N/LTS-500N
Feature
  • E Strength test by easy operation
    E   Epoch-making design
    Prominent digital display, Good operational key arrangement, Secure the space for work & jig.
    E   Possible to test of tension / compression / bending
    Power of opening a letter of bag, Adhesive strength/peel power, Tractive effort of film, Measurement of defective extraction forces of press fit and rivet parts,
    Because of the adopting the encoder to measure the displacement, it can be measured with the resolution of 0.01 mm.
    E   Equipped a convenient function and safety devices.
    Automatic inverting function (set by load or displacement), Peak detecting function, Change for display range of testing force (1 time / 10 times), Automatic zero function, registration of load cell, Sample rupture detecting function, Communication function (USB 2.0/1.1 conforming), Overload prevention function, Load cell, Data collecting software, attached standard communication cable.
Specifications
Parts No. LTS-200N-S300
LTS-200N-S100
LTS-200N-S50
LTS-200N-S20
LTS-500N-S100
LTS-500N-S50
LTS-500N-S20
Maximum testing force 200 N 500 N
Movable crosshead stroke 0 to 310 mm
(with optional chuck PCH-500N-012)
Speed range  
Standard test speed S300 : 30, 50, 100, 150, 200, 300 mm/min
S100 : 10, 20, 30, 50, 75, 100 mm/min
S50 : 5, 10, 20, 30, 40, 50 mm/min
S20 : 1.5, 2, 5, 10, 15, 20 mm/min
Return speed Testing speed or RAPID RETURN
with over-shootless function
Speed Accuracy }3 % of setting speed (in no load)
Displacement accuracy Resolution 0.01 mm
Display of testing force 4 digit digital display
Range 1 : -200.0 to 200.0/-500.0 to 500.0
Range 10 : -20.00 to 20.00/-50.00 to 50.00
Measuring range Selectable from 1 time or 10 times
Measuring accuracy 1 time range: }0.1 %F.S., 10 times range : }0.5 %F.S.
(Full scale is depending on the rated capacity of load cell)
Peak hold function Single peak hold function (Automatic reset when starting)
Auto zero Automatic zero adjustment by "ZERO" key.
Analog output DC-5 V to 5 V (Output connector : BNC31-OUT)
Safety equipment ---
limit switch for overload Possible to set them to the optional positions in the moving range of the crosshead
Emergency stop switch When operating, all the power supply is turn off.
Prevent overload Movable crosshead stops when load value reaches 102 % of F.S.
Communication
(USB port)
Comformed to USB2.0/1.1 (Connector : B type),
Communication frequency : 20 times/s
Operating temp./humidity range Temperature 5 to 40 ,
Humidity 20 % to 80 %RH (Non condensing)
Power supply voltage Single phase AC100 V}10 V 50/60 Hz
Power consumption Approx. 300 VA
Outline dimensions(WxHxD) 475 mm x 710 mm x 347 mm (excludes protruding parts)
Weight Approx. 17 kg
Options
Cable for analog output
Download Terms and Conditions
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
LTS-200N-500N (952KB) No.4149 (272KB) ---
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.