NS10T (- H) series |
 |
 |
|
-
|
 |
|
| E |
|
High accurate measurement of compound pressure is possible. |
| E |
|
Natural frequency : 72 kHz~1 278 kHz |
| E |
|
Accuracy 0.2 %R.O. |
| E |
|
Temperature environment 150 or less is possible.
|
| * |
|
Application
Automatic transmission or engine test stand.
Changeable valve lift mechanism testing instrument and various test benches, Solenoid valve experiment device, Calorie meter, CO2 compressor, Flow measurement device |
-
|
|
 |
|
| Parts No. |
NS10T |
NS10T-H |
| Rated capacity |
200 kPa~50 MPa |
200 kPa~20 MPa |
| Safe overload |
200
%R.C. |
| Ultimate overload |
300
%R.C. |
| Accuracy |
}0.2
%R.O. (including non-linearity, hysteresis and repeatability) |
| Rated output |
1.5
mV/V}0.15 mV/V
(NS10T-200KP(-H) : 1.0 mV/V}0.10 mV/V) |
| Excitation, recommended |
DC10
V or less |
| Excitation, maximum |
DC30 V |
DC15 V |
| Zero balance |
}0.05
mV/V |
| Input resistance |
700
~ 900 |
| Output resistance |
700
~ 900 |
| Insulation resistance |
1
000 M or more (DC 50 V) |
| Temp. range, compensated |
-20 ~ 70 |
-30 ~ 150
|
| Temp. range, safe |
-30 ~ 80 |
-40 ~ 165
|
| Temp. effect on zero |
}0.2
%R.O./10 |
| Temp. effect on output |
}0.2
%LOAD/10 |
| Class of protection |
IP55 |
IP65 |
| Material of pressure hole |
Stainless steel
(SUS340L) |
| Material of diaphragm |
Saphire |
| Mounting screw |
1/8 1/4 3/8 G{PF}, R{PT} |
| Tightening torque |
20
Nm ~ 40 Nm |
| Cable |
4.7, shielded 2 m cable directly attached, cable end is separated |
3.8, shieleded 2 m oil proofed cable directly attached, cable end is separated |
| Weight |
Approx. 200
g (main body only) |
|
 |
|
| Parts No. |
Rated capacity |
| NS10T-200KP(-H) |
200 kPa |
| NS10T-500KP(-H) |
500 kPa |
| NS10T-1MP(-H) |
1 MPa |
| NS10T-2MP(-H) |
2 MPa |
| NS10T-5MP(-H) |
5 MPa |
| NS10T-10MP(-H) |
10 MPa |
| NS10T-20MP(-H) |
20 MPa |
| NS10T-30MP |
30 MPa |
| NS10T-35MP |
35 MPa |
| NS10T-50MP |