NS104
series
|
 |
 |
|
-
|
 |
|
| E |
|
Accuracy : 0.5 %R.O. including zener barrier
(0.2 %R.O. is possible by conbination adjustment separately.) |
| E |
|
Possible to measure the compound pressure and absolute pressure with high level accuracy. |
| E |
|
Approved Ex ia IIC T4 of intrinsically safe explosion proofed measurement (Technical standard) |
|
|
Application
Manifold type pressure of oils and fats
Hydrogen gas supply pressure and meter |
|
|
 |
|
| Rated capacity |
100 kPa ~ 50
MPa |
| Safe overload |
200 %R.C. |
| Ultimate overload |
300 %R.C. |
| Accuracy |
0.5 %R.O. (including non-linearity, hysteresis and repeatability) |
| Rated output |
Current : 4 mA ~ 20 mA (2-wires method, Load resistance
500 or less, at 24 V) |
| Power supply voltage |
DC 24 V (20 V ~ 35
V) |
| Insulation resistance |
1 000 M or more |
| Temp. range, compensated |
-20 ~ 60 |
| Temp. range, safe |
-30 ~ 80 |
| Temp. effect on zero |
0.5 %R.O./10 |
| Temp. effect on output |
0.5 %LOAD/10 |
| Cable |
4.7, shielded cable2 m directly attached, cable end is separated(Cable directly attached type) |
| Class of protection |
IP43 |
| Material of pressure hole |
Stainless steel (SUS304L) |
| Material of cover |
Aluminum alloy (with almite processing) |
| Material of pressure diaphragm |
Single crystal sapphire |
| Mounting screw |
1/8 1/4 3/8 G{PF}, R{PT} |
| Weight |
Approx. 200 g (Cable directly attached type, and main body only.)
Approx. 400 g (Terminal box type, and main body only) |
| Tightening torque |
20 Nm ~ 40 Nm |
|
 |
|
| Parts No. |
Rated capacity |
| NS104-100KP*-1*** |
1 kPa |
| NS104-200KP*-1*** |
200 kPa |
| NS104-500KP*-1*** |
500 kPa |
| NS104-1MP*-1*** |
1 MPa |
| NS104-2MP*-1*** |
2 MPa |
| NS104-2.5MP*-1*** |
2.5 MPa |
| NS104-3MP*-1*** |
3 MPa |
| NS104-3.5MP*-1*** |
3.5 MPa |
| NS104-5MP*-1*** |
1 MPa |
| NS104-10MP*-1*** |
10 MPa |
| NS104-20MP*-1*** |
20 MPa |
| NS104-25MP*-1*** |
25 MPa |
| NS104-30MP*-**** |
30 MPa |
| NS104-35MP*-**** |
35 MPa |
| NS104-50MP*-**** |
50 MPa |
|
 |
|
| |