Force sensor LSMS-*-S06

MST - 10kN
Feature
  • E   Compact force sensor specialized to use for mold cavity pressure measurement system.
    E   Achieve the small size, high accuracy and the low price by in-house strain gage technology.
    E   Excellent in noise-proof by 4-gage method, and do not receive the temperature effect easily even if the sensor is built into the metal mold with high temperature.
    E   A free metal mold design that doesn’t receive the restriction of the ejector pin diameter can be designed because of the method set up in the ejector pin bottom used.
Specifications
Rated capacity 196.1 N {20 kgf} ~ 29.42 kN {3 tf}
Safe overload 150 %R.C.
Ultimate overload 200 %R.C.
Rated output 0.6 mV/V±0.1 mV/V
Non-linearity 1 %R.O. (LSMS-500K-S06: 1.5 %R.O.)
Hysteresis 1 %R.O.
Repeatability

1 %R.O.

Recomended excitation 5 V
Maximum excitation 12 V
Zero balance ±0.1 mV/V
Input terminal resistance LSMS-20K~100K-S06: 355 Ω±5 Ω,
LSMS-200K/-500K-S06: 355 Ω±20 Ω,
LSMS-1T-S06: 358 Ω±20 Ω, LSMS-3T-S06: 350 Ω±20 Ω,
Output terminal resistance LSMS-20K~100K-S06: 355 Ω±5 Ω,
LSMS-200K/-500K-S06: 355 Ω±20 Ω,
LSMS-1T-S06: 358 Ω±20 Ω, LSMS-3T-S06: 350 Ω±20 Ω,
Insulation resistance 1 000 MΩ or more (at DC50 V) (between bridge and main body)
Cinoebsated tenoeratyre range -10 ` 150
Safe temperature range -20 ` 150
Temp. effect on zero balance 1.0 %R.O./10
Temp. effect on output 1.0 %LOAD/10
Cable LSMS-20K`100K-S06: φ1.0, 4-cores 1.2 m shielded cable with connector at cable end.
LSMS-200K~500K-S06: φ1.0, 4-cores 1.5 m shielded cable with connector at cable end.
LSMS-1T-S06: φ1.8, 4-cores 2 m shielded cable with connector at cable end.
LSMS-3T-S06: φ3.2, 4-cores 2 m shielded cable with connector at cable end.
Minimum bending radius of cable LSMS-20K`500K-S06: 5 mm, LSMS-1T-S06: 10 mm,
LSMS-3T-S06: 16 mm
Class of protection IP64 or equivalent
Material Stainless steel HRC42 or more
Fatigue life 1 000 000 times at rated load
Weight LSMS-20K`50K-S06: Approx. 2 g,
LSMS-100K`500K-S06: Approx. 3 g,
LSMS-1T-S06: 10 kg, LSMS-3T-S06: 30 kg
Options
Molding pressure conversion module (MPC-201-25)
Parts No
Parts No. Rated capacity Natural frequency
(Hz)
Rated displacement
(mm) (for reference)
External size
(mm)
LSMS-20K-S06 196.1 N {20 kgf} 67 000 0.003 φ7.0 x 5
LSMS-50K-S06 490.3 N {50 kgf} 62 000 0.005
LSMS-100K-S06 980.7 N {100 kgf} 85 000 0.005 φ10.0 x 5
LSMS-200K-S06 1.961 kN {200 kgf} 195 000 0.009 φ10 x 5.5
LSMS-500K-S06 4.903 kN {500 kgf} 184 000 0.015 φ10 x 8
LSMS-1T-S06 9.807 kN {1 tf} 127 000 0.013 φ15 x 9.5
LSMS-3T-S06 29.42 N {3 tf} 110 000 0.036 φ16 x 16
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
LSMS-20K/50K-S06 (292KB)
LSMS-100K-S06 (202KB)
LSMS-200K-S06 (207KB)
LSMS-500K-S06 (204KB)
LSMS-1T-S06 (210KB)
LSMS-3T-S06 (339KB)
LSMS-20K/50K-S06
No.KT53854-2 (191KB)
LSMS-100K-S06
No.KT53948-2 (183KB)
LSMS-200K`3T-S06
No.KT54547-2 (205KB)
Sensor selecting method
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.