Products Topics Introduction Contact us

Home > Products > Load Cell > Tension type for industrial weighing systems > U3B1 - B

Load Cell

U3B1 - B series

U3B1 - B
* Rod end is optional.
Feature
  • High accuracy, tension / compression service load cell.
Specifications
Rated capacity 196.1 N{20 kgf}~9.807 kN{1 tf}
Safe overload 150 %R.C.
Ultimate overload 200 %R.C.
Rated output 3 mV/V}0.015 mV/V
Non-linearity 0.05 %R.O.
Hysteresis 0.05 %R.O.
Repeatability 0.03 %R.O.
Excitation, recommended 10 V or less
Excitation, maximum 15 V
Zero balance }0.03 mV/V
Input resistance 350 }3.5
Output resistance 350 }5
Insulation resistance 2 000 M or more (DC50 V) (between bridge and main body)
Temp. range, compensated -10 ~ 70
Temp. range, safe -20 ~ 80
Temp. effect on zero 0.05 %R.O./10
Temp. effect on output 0.1 %LOAD/10
Cable 6.3, 4-cores shielded 3 m cable 3 m directly attached, Y-type crimp terminal lugs are attached at cable end.
Class of protection IP64 or equivalent
Material of element U3B1-20K~200K-B : Alluminium alloy
U3B1-500K~1T-B : Alloy steel
Durability 1 000 000 times with rated load applied.
Options
load button, Spherical rod end
Parts No
Parts No. Rated capacity Natural frequency Rated displacement Weight
U3B1-20K-B 196.1 N {20 kgf} 600 Hz 0.18 mm Approx.0.33 kg
U3B1-50K-B 490.3 N {50 kgf} 1 100 Hz 0.16 mm
U3B1-100K-B 980.7 N {100 kgf} 1 600 Hz 0.14 mm
U3B1-200K-B 1.961 kN {200 kgf} 2 100 Hz 0.12 mm
U3B1-500K-B 4.903 kN {500 kgf} 2 600 Hz 0.14 mm Approx.0.63 kg
U3B1-1T-B 9.807 kN {1 tf} 3 000 Hz 0.12 mm
Download
CAD files (DXF) Specification sheet (PDF) Instruction Manual (PDF)
U3B1-20K`50K-B (82KB)
U3B1-100K-B (82KB)
U3B1-200K`1T-B (82KB)
No.K102767-2 (157KB) No.KT60247-1 (53KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.