2 000 M or more(DC50
V)(between bridge and main body)
Temp. range, compensated
-10 ~ 50
Temp. range, safe
-10 ~ 70
Temp. effect on zero
0.05 %R.O./10
Temp. effect on output
0.02 %LOAD/10
Cable
4.7, 4-cores shielded
148.5 cm cable directly attached, and cable end
is separated.
Class of protection
IP64
Material of element
Alluminium alloy
Durability
1 000 000 times with
rated load applied.
Effect of eccentric load
- Size of loading
plate is 450 mm x 600 mm at maximum.
- The center of loading plate and the center of
load cell should be the same position
- Error is within 0.02 %R.O. applied with 1/2 of
rated capacity at the position of 15 mm of eccentricity.