2 000 M or more (DC50
V)(between bridge and main body)
Temp. range, compensated
-10 ~ 50
Temp. range, safe
-10 ~ 50
Temp. effect on zero
0.04 %R.O./10
Temp. effect on output
0.012 %LOAD/10
Cable
4.7, 4-cores shielded
5 m cable directly attached, and cable end is
separated.
Class of protection
IP67 or equivalent
Material of element
Stainless steel
Durability
1 000 000 times with
rated load applied.
Effect of eccentric load
- Size of loading
plate is 400 mm x 400 mm at maximum.
- The center of loading plate and the center of
load cell should be the same position
- Error is within 0.01 %R.O. applied with 1/2 of
rated capacity at the position of 100 mm of eccentricity.
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.