2 000 M or more (DC50
V)(between bridge and main body)
Temp. range, compensated
-10 ~ 50
Temp. range, safe
-10 ~ 50
Temp. effect on zero
0.04 %R.O./10
Temp. effect on output
0.0P2 %LOAD/10
Cable
3.2, 4-cores shielded
40 cm cable directly attached, and cable end is
separated.
Class of protection
IP64
Material of element
Alluminium alloy
Durability
1 000 000 times with
rated load applied.
Effect of eccentric load
- Size of loading
plate is 400 mm x 400 mm at maximum.
- The center of loading plate and the center of
load cell should be the same position
- Error is within 0.01 %R.O. applied with 1/2 of
rated capacity at the position of 100 mm of eccentricity.