2 000 M or more (DC50
V) (between bridge and main body)
Temp. range, compensated
-10 ~ 50
Temp. range, safe
-10 ~ 50
Temp. effect on zero
0.04 %R.O./10
Temp. effect on output
0.012 %LOAD/10
Cable
3.2, 4-cores shielded
40 cm cable directly attached and cable ends is
separated.
Class of protection
IP64 or equivalent
Material of element
Alluminium alloy
Durability
1 000 000 times with
rated load applied
Effect of eccentric load
E C2G1-6K to 35K
- Size of loading plate is 300 mm x 300 mm at maximum.
- The center of loading plate and the center of
load cell should be the same position
- Error is within 0.02 %R.O. applied with 1/2 of
rated capacity at the position of 75 mm of eccentricity.
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.