High capacity and applicable for commercial scale.
Because the output voltage is adjusted, it is available in both single point / multipoint.
Rated capacity
980.7
N {100 kgf} ~ 7.845 kN {800 kgf}
Safe overload
150 %R.C.
Ultimate overload
200 %R.C.
Rated output
2 mV/V({0.004, -0)mV/V
Non-linearity
0.02 %R.O.
Hysteresis
0.02 %R.O.
Repeatability
0.02 %R.O.
Creep
0.025 %R.O./20 min
Creep recovery
0.025 %R.O./20 min
Excitation, recommended
12 V or less
Excitation, maximum
16 V
Zero balance
}0.1 mV/V
Input resistance
420 }40
Output resistance
350 }3
Insulation resistance
2 000 M or more (DC50 V) (between bridge and main body)
Temp. range, compensated
-10 ~ 50
Temp. range, safe
-20 ~ 70
Temp. effect on zero
0.05 %R.O./10
Temp. effect on output
0.02 %LOAD/10
Cable
6.3, 4-cores shielded 6 m cable directly attached, Y-crimp type terminal lugs are attached at cable
end.
Class of protection
IP65
Material of element
Alluminium alloy
Durability
1 000 000 times with
rated load applied.
Effect of eccentric load
The size of loading plate : 450 mm x 650
mm at maximum.
The center of loading plate and also the center of load cell should be the same position.
Error is within 0.02 %R.O. applied with 1/2 of
rated capacity at the position of 200 mm of eccentricity.
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.