Products Topics Introduction Contact us

Home > Products > Load Cell > Single point type for commercial scale > C2D1

Load Cell

C2D1 series

C2D1
Feature
  • High capacity and applicable for commercial scale.
  • Because the output voltage is adjusted, it is available in both single point / multipoint.
Specifications
Rated capacity 980.7 N {100 kgf} ~ 7.845 kN {800 kgf}
Safe overload 150 %R.C.
Ultimate overload 200 %R.C.
Rated output 2 mV/V({0.004, -0)mV/V
Non-linearity 0.02 %R.O.
Hysteresis 0.02 %R.O.
Repeatability 0.02 %R.O.
Creep 0.025 %R.O./20 min
Creep recovery 0.025 %R.O./20 min
Excitation, recommended 12 V or less
Excitation, maximum 16 V
Zero balance }0.1 mV/V
Input resistance 420 }40
Output resistance 350 }3
Insulation resistance 2 000 M or more (DC50 V) (between bridge and main body)
Temp. range, compensated -10 ~ 50
Temp. range, safe -20 ~ 70
Temp. effect on zero 0.05 %R.O./10
Temp. effect on output 0.02 %LOAD/10
Cable 6.3, 4-cores shielded 6 m cable directly attached, Y-crimp type terminal lugs are attached at cable end.
Class of protection IP65
Material of element Alluminium alloy
Durability 1 000 000 times with rated load applied.
Effect of eccentric load The size of loading plate : 450 mm x 650 mm at maximum.
The center of loading plate and also the center of load cell should be the same position.
Error is within 0.02 %R.O. applied with 1/2 of rated capacity at the position of 200 mm of eccentricity.
Parts No
Parts No. Rated capacity
C2D1-100K 980.7 N {100 kgf}
C2D1-300K 2.942 kN {300 kgf}
C2D1-450K 4.413 kN {450 kgf}
C2D1-600K 5.884 kN {600 kgf}
C2D1-800K 7.845 kN {800 kgf}
Download
CAD files (DXF) Specification sheet (PDF) ---
C2D1-100K (38KB)
C2D1-600K (32KB)
No.214051 (67KB) ---
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.