Home
>
Products
>
Load Cell
>
Force sensor
> FSI
-
Compression Type
-
Tension Type
-
Single Point Type
-
Force Sensor
-
Special Application Usage
-
Mounting Attachment
-
Selected by Rated Capacity
FSI series
Aluminium full bridge gage load cell
Rated output
19.61 N {2 kgf} ~ 196.1 N {20 kgf}
Safe overload
150 %R.C.
Rated output
-1.58 mV/V}0.158 mV/V ~ -2.14 mV/V}0.214 mV/V (See below)
Non-linearity
0.05 %R.O.
Hysteresis
0.05 %R.O.
Repeatability
0.05 %R.O.
Creep
0.15 %R.O./1 min
Creep recovery
0.15 %R.O./1 min
Excitation, recommended
5 V or less
Excitation, maximum
8 V
Zero balance
}1 mV/V
Input resistance
350 }35
Output resistance
350 }35
Insulation resistance
1 000 M or more (DC50 V) (between bridge and main body)
Temp. range, compensated
-10 ~ 50
Temp. range, safe
-10 ~ 50
Temp. effect on zero
1 %R.O./10
Temp. effect on output
1 %LOAD/10
Class of protection
IP00 or equivalent
Material of element
Alluminium alloy
Durability
1 000 000 times with rated load applied.
Parts No.
Rated capacity
Rated output (mV/V)
Weight (Approx.g)
FSI-2K
19.61 N {2 kgf}
- 1.58}0.158
5
FSI-10K
98.07 N {10 kgf}
- 2±0.2
7
FSI-20K
196.1 N {20 kgf}
- 2.14}0.214
10
CAD files (DXF)
Specification sheet (PDF)
Instruction Manual (PDF)
FSI-2K (32KB)
FSI-10K (32KB)
FSI-20K (32KB)
FSI-2K
No. K505108-2-H (138KB)
FSI-10K
No. K504103-2-I (146KB)
FSI-20K
No. K505109-2-J (142KB)
No.KT60248-1 (41KB)