Canister type load cell with safe overload
capacity.
Suitable for the weighing system where overload is temporarily caused by falling the measured goods.
Rated capacity
4.903
kN {500 kgf}~196.1 kN {20 tf}
Safe overload
500 %R.C.
Ultimate overload
500 %R.C.
Rated output
2 mV/V}0.008 mV/V
Non-linearity
0.2 %R.O.
Hysteresis
0.1 %R.O.
Repeatability
0.1 %R.O.
Excitation, recommended
12 V or less
Excitation, maximum
20 V
Zero balance
}0.02 mV/V
Input resistance
350 }3.5
Output resistance
350 }5
Insulation resistance
2 000 M or more (DC50
V)
(between bridge and main body)
Temp. range, compensated
-10 to 70
Temp. range, safe
-20 to 100
Temp. effect on zero
0.05 %R.O./10
Temp. effect on output
0.1 %LOAD/10
Cable
10, 4 -cores shielded
3 m cable directly attached,
Y-crimp type terminal lugs are attached at cable
end.
Class of protection
IP64
Material of element
Alloy steel
Paint
Painted by epoxy resin
(Munsell 6GY3.5/2 half-polished resemblance color)