Home > Products > Digital Indicator > CSD - 907

Digital Indicator

Feeder controller CSD-907

Feeder Controller CSD-907
Feature
  • E   Liquid crystal display with LED back light.
    E   SV values available by the external analog input.
    E   Accumulated values output externally.
    E   Up to 5 sets of the instruments can be used together by changing Master/Slave.
    E   2 systems of analog outputs (4 mA ~ 20 mA) can be prepared.
Specifications
Bridge power supply DC10 V}0.3 V within 120 mA@
(Changeable to DC2.5 V or DC5 V) with remote sensing function
Input range F.S. setting can be available at the input from 0.3 mV/V to 3 mV/V.
(when bridge power supply is DC10 V)
Zero adjustment range 0 mV/V ~ 2.4 mV/V
Non-linearity 0.01 %F.S.
Temperature coefficient Zero point }0.2 V/ (Input conversion)
Sensitivity }0.001 5 %F.S./
Analog filter 1 Hz on bessel characteristics
Load display Display of gross weight or flow rate value
Display of setting SV value and PV value
Display range 0 ~ 99 999
Display of operation status ZERO, MA/SL, RE/LO, AUTO, VOLU., SUPPLY
Display 128 x 64 dots liquid crystal display
(with back light LED type)
Display times 2 times/s
Condition display RUN, ALARM (LEDlight on)
External control output Signal of multiplication(pulse output), Signal of powder request, Alarm of upper limit, Alarm of lower limit, Alarm of flow rate declination, Out of control, RUN
External control input Start control, Signal of supplied powder, Signal of REMOTE MODE, Reset the multiplication
Serial interface output for transmitting the flow rate value Serial interface with 2 wires method
Analog output for inverter control Output 4 mA ~ 20 mA (Load resistance@ 510 or less)
Accuracy 0.05 %F.S. (Resolution 1/30 000)
with scaling function
Analog output for transmitting the flow rate value Output 4 mA ~ 20 mA (Load resistance@510 or less)
Accuracy 0.05 %F.S. (Resolution@ 1/30 000)
with scaling function
Analog input for receiving the flow rate value Input 4 mA ~ 20 mA (Input resistance 100 )
Accuracy 0.05 %F.S. (Resolution 1/30 000)
with scaling function
Operating temp./humidity range Temperature 0 ~ 50 , Humidity 85 %RH or less
(Non condensing)
Power supply voltage AC100 V (AC85 V ~ AC100 V) 50/60 Hz
Power consumption Approx. 19 VA
Outline dimensions(WxHxD) 192 mm x 96 mm x 175 mm (excludes protruding parts)
Weight Approx. 2.5 kg (without options)
Download
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
CSD-907 (457KB) No.382907 (90KB) No.294-1115 (1,525KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.