Feeder
controller CSD-907 |
 |
 |
|
-
|
 |
|
| E |
|
Liquid crystal display with LED back
light. |
| E |
|
SV values available by the external
analog input. |
| E |
|
Accumulated values output externally. |
| E |
|
Up to 5 sets of the instruments can
be used together by changing Master/Slave. |
| E |
|
2 systems of analog outputs (4 mA ~
20 mA) can be prepared. |
|
|
 |
|
| Bridge power supply |
DC10 V}0.3
V within 120 mA@
(Changeable to DC2.5 V or DC5 V) with remote sensing
function |
| Input range |
F.S. setting can be
available at the input from 0.3 mV/V to 3 mV/V.
(when bridge power supply is DC10 V) |
| Zero adjustment range |
0 mV/V ~ 2.4 mV/V |
| Non-linearity |
0.01 %F.S. |
| Temperature coefficient |
Zero point }0.2 V/ (Input
conversion)
Sensitivity }0.001 5 %F.S./ |
| Analog filter |
1 Hz on bessel characteristics |
| Load display |
Display of gross weight
or flow rate value |
| Display of setting |
SV value and PV value |
| Display range |
0 ~ 99 999 |
| Display of operation
status |
ZERO, MA/SL, RE/LO, AUTO, VOLU., SUPPLY |
| Display |
128 x 64 dots liquid
crystal display
(with back light LED type) |
| Display times |
2 times/s |
| Condition display |
RUN, ALARM (LEDlight
on) |
| External control output |
Signal of multiplication(pulse
output), Signal of powder request, Alarm of upper
limit, Alarm of lower limit, Alarm of flow rate
declination, Out of control, RUN |
| External control input |
Start control, Signal
of supplied powder, Signal of REMOTE MODE, Reset
the multiplication |
| Serial interface output
for transmitting the flow rate value |
Serial interface with
2 wires method |
| Analog output for
inverter control |
Output 4 mA ~ 20 mA
(Load resistance@ 510 or less)
Accuracy 0.05 %F.S. (Resolution 1/30 000)
with scaling function |
| Analog output for
transmitting the flow rate value |
Output 4 mA ~ 20
mA (Load resistance@510 or less)
Accuracy 0.05 %F.S. (Resolution@ 1/30 000)
with scaling function |
| Analog input for receiving
the flow rate value |
Input 4 mA ~ 20 mA
(Input resistance 100 )
Accuracy 0.05 %F.S. (Resolution 1/30 000)
with scaling function |
| Operating temp./humidity range |
Temperature 0 ~
50 , Humidity 85 %RH or less
(Non condensing) |
| Power supply voltage |
AC100 V (AC85 V ~
AC100 V) 50/60 Hz |
| Power consumption |
Approx. 19 VA |
| Outline dimensions(WxHxD) |
192 mm x 96 mm x 175
mm (excludes protruding parts) |
| Weight |
Approx. 2.5 kg (without options) |
|
 |
|
| CAD files (DXF) |
Specification sheet (PDF) |
Instruction manual (PDF) |
| CSD-907
(457KB) |
No.382907
(90KB) |
No.294-1115
(1,525KB) |
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here. |
|
| |