Digital
Peak Holder CSD-819C |
 |
 |
|
-
|
 |
|
| E |
|
High speed sampling at 2 000 times/s
with the small unit. |
| E |
|
Various peak mode setting. |
| E |
|
Automatic calibration function automatically adjust span. |
| E |
|
Mark applied. |
| E |
|
Suitable for the press fit measuring
|
|
|
 |
|
| Bridge power supply |
DC10 V}0.5
V within 60 mA
(Changeable to DC5 V or DC2.5 Vj |
| Input range |
F.S. setting is available
at the input range from }0.4 mV/V to }3.1 mV/V
iWhen bridge power supply is DC10 V or DC5 Vj
F.S. setting is available at the input range from
}0.8 mV/V to }3.1 mV/V
iWhen bridge power supply is DC2.5 Vj |
| Output range |
DC}10 V Load resistance
5 kΆor more
(F.S. setting is available in the function.) |
| Output times |
100 times/s, 500 times/s,
1 000 times/s, 2 000 times/s (Synchronous with A/D
sampling rate.) |
| Output resolution |
Same as the display
resolution. |
| Zero adjustment range |
}2.0 mV/V |
| Non-linearity |
Display 0.025 %F.S.
Output 0.025 %F.S. |
| Temperature coefficient |
Zero point }0.5 ΚV/
(Input conversion, in F.S. setting at the input of
}0.5 mV/V to 3.1 mV/V)
Sensitivity }0.01 %F.S./ (Input conversion, F.S.
setting at the input of }0.5 mV/V to 3.1 mV/V) |
| Input filter |
10 Hz, 100 Hz, 1 kHz |
| A/D sampling |
2 000 times/s
(Changeable to 100 times/s, 500
times/s, 1 000 times/s) |
| Load display |
-11 000 to 11 000 |
| Comparator display |
-99 999 to 99 999 |
| Nos. of display |
1 point (Selectable
from S0, S1, S2, S3 or S4) |
| Display times |
20 times/s (Changeable to 4 times/s, 50 times/s or 100
times/s) |
| External control function |
ZERO, PEAK/TRACK, HOLD, RESET, SEL.1, SEL.2 |
| Comparator function |
|
| Display range |
-99 999 to 99 999 |
| Nos. of display |
1 point (Selectable
from S0, S1, S2, S3 or S4) |
| Display times |
20 times/s (Changeable to 4 times/s, 50 times/s or 100
times/s) |
| Open collector output
function |
5 points of S0, S1, S2, S3 or
S4 |
| Operating temp./humidity range |
Temperature -10
to 50 , Humidity 85 %RH or less
(Non condensing) |
| Power supply voltage |
AC100 V to AC240 V
50/60 Hz
(Permissible variable range AC85 V to AC264
V) |
| Power consumption |
Approx.15 VA (without
options, at AC100 V)
Approx.18 VA at maximum
(with options, at AC100 V to 240 V) |
| Outline dimensions(WxHxD) |
96 mm x 96 mm x 129.5
mm (excludes protruding parts) |
| Weight |
Approx. 500 g (without options) |
|
 |
|
| Current output, BCD
output, RS-232C interface, RS-422/485 interface |
|
 |
|
| CAD files (DXF) |
Specification sheet (PDF) |
Instruction manual (PDF) |
|
CSD-819C (480KB) |
No.382819C (194KB) |
No.294-1240 (2,139KB) |
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here. |
|
| |