Digital indicator with 50 dot bar meter display CSD-531

Digital Indicator CSD-531
Feature
  • E   50 dot bar meter display with the digital display.
    E   Setting value of 2 points of upper limit, one point of upper/lower limit, 2 points of lower limit is available.
    E   Automatic calibration by registering the rated output data (X.XXX mV/V) of strain gage applied transducers is performed.
    E   Power supply : AC100 V to AC240 V
Specifications
Bridge power supply DC5 V}0.25 V within 60 mA (Changeable to DC2.5 Vj
Input range F.S. setting can be made at the input range from }0.4 mV/V to }3.1 mV/V iAt the time of DC5 V for bridge power supply.j
Output range DC4 mA to 20 mA
(At the time of 0.4 mV/V for the bridge power supply)
Load resistance 260 ƒΆ or less
Output times Changeable to 4 times/s, 20 times/s or 50 times/s
(Synchronized with display rate)
Non-linearity 0.1 %F.S.
Temperature efficient Zero point }0.5 ƒΚV/Ž, Sensitivity }0.02 %F.S./Ž (Input conversion)
Input noice }0.6 ƒΚVp-p or less
(At the default setting for digital filter and stabilized filter)
A/D sampling 100 times/s
Load display  
Display range -9 999 to {9 999 (Changeable to x 2, x 5 or x 10)
Bar meter display Red or Green 50 dots bar meter displays the ratio of the current load value comparing with the maximum display value, or the ratio of the set value of the comparator S1 or S2 comparing with the maximum display value.
Display times 4 times/s (Changeable to 20 times/s or 50 times/s)
External control function ZERO, HOLD
Comparator function  
Set value -9 999 to {9 999
Set quantity 2 points of S1and S2
Comparator conversion rate Changeable to 4 times/s, 20 times/s or 50 times/s
(Synchronous with display rate)
Contact output function S1, S2 Output the contact when less than/or more than the comparator set value is obtained.
S0 Short of contact at the time of whichever condition as follows is set.
- When the condition is full(100 % of rated load)
- When the load is between the set value of S1 and S2
contact output 1a contact
AC125 V : 3 A (Load resistance)
DC30 V : 3 A (Load resistance)
Operating temp. /humidity range 0 Ž to 50 Ž / 85 %RH or less (Non condensing)
Power supply voltage

AC100 V to 240 V 50/60 Hz
(Permitted changeable range from AC85 V to 264 V)

Outline dimensions(WxHxD) 110 mm x 110 mm x 205 mm (excludes protruding parts)
Weight Approx. 1.4 kg (without options)
Options
Voltage output
Download Terms and Conditions
CAD files (DXF) Specification sheet (PDF) Instruction manual (PDF)
CSD-531 (354KB) No.EN382531 (73KB) No.294-1114 (2,073KB)
Adobe Acrobat Reader is required to refer the Specification data sheet.
Acrobat Reader is a registered trademark of Adobe Systems Ltd.
The download of Adobe Acrobat Reader is here.