Products Topics Introduction Contact us

Home > Products > Digital Indicator > Accessories > Z961 / Z964

計装用アクセサリ

Zener barrier Z961-TC20162 / Z964-TC20163

Z961 / Z964
Feature
  • Safety barrier for load cell to be used for intrinsic safety explosion proof weighing system.
    Meets the intrinsic safety explosion proof requirement of Technology Institution of Industrial safety in Japan.
    The type of Z951/Z964 to be applied is different in the model passed before 2011 and the model passed after 2012.
Barrier Z961/Z964 Passed before 2011 Barrier Z961/Z964 passed after 2012
Specifications
Model No. Z961-TC20162 Z964-TC20163
Hazardous Area Terminals 1 & 2 or Terminals 1 & 3
Uo= 8.7 V 12 V
Io= 89 mA 12.3 mA
Po= 0.1931 W 0.04 W
Lo= 4.48 mH 235 mH
Co= 5.9 μF 1.41 μF
Terminals 2 & 4 or Terminals 3 & 4
Uo= 8.7 V 12 V
Io= 89 mA 12.3 mA
Po= 0.1931 W 0.04 W
Lo= 4.48 mH 235 mH
Co= 5.9 μF 1.41 μF
Terminals 1, 4 & 2 or Terminals 4 & 3
Uo= 8.7 V 12 V
Io= 178 mA 24.5 mA
Po= 0.39 W 0.08 W
Lo= 1.12 mH 59.2 mH
Co= 5.9 μF 1.41 μF
Terminals 1 & 4
Uo= 17.4 V 24 V
Io= 89 mA 12.3 mA
Po= 0.39 W 0.08 W
Lo= 4.48 mH 235 mH
Co= 0.346 μF 0.125 μF
Non−Hazadous Area
Um=
AC250 V, 50/60 Hz
DC250V
Ambient Temperature −20 ℃ to 60 ℃
Weight Approx.142 g
Applied model (After 2012)
C2B1B、C2B1B-C3、CC010-C3、CMP1J
Plan
Download ご利用条件
CAD files (DXF) Specification sheet (PDF) ---
Z961/Z964 (30KB) Z961-TC20162
No.3538912 (89KB)
Z964-TC20163
No.3538913 (96KB)
---
Adobe Acrobat Reader is required to refer the Specification data sheet.