;=============================================================================== ; Mineba Co., Ltd Measuring Components BU ; Device type Slave(CSD912-P70) ;Protocol type DP-V1 ; GSD Rev 1.00 ; Revision log: ; 1.00 2008-11-27 First release ;=============================================================================== #Profibus_DP GSD_Revision = 5 ; Device identification Vendor_Name = "Mineba Co., Ltd" Model_Name = "CSD912-P70" Revision = "1.00" Ident_Number = 0x0BF1 Protocol_Ident = 0 ; DP protocol Station_Type = 0 ; Slave device FMS_supp = 0 ; FMS not supported Slave_Family = 0 ; General device Hardware_Release = "Version 1.00" Software_Release = "Version 1.00" ; Supported hardware features Redundancy = 0 ; not supported Repeater_Ctrl_Sig = 2 ; TTL 24V_Pins = 0 ; not connected Implementation_Type = "NP30" ; Supported DP features Freeze_Mode_supp = 1 ; supported Sync_Mode_supp = 1 ; supported Auto_Baud_supp = 1 ; supported Set_Slave_Add_supp = 1 ; supported Fail_Safe = 1 ; supported ; Supported baudrates 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; Maximum responder time for supported baudrates MaxTsdr_9.6 = 15 MaxTsdr_19.2 = 15 MaxTsdr_45.45 = 15 MaxTsdr_93.75 = 15 MaxTsdr_187.5 = 15 MaxTsdr_500 = 15 MaxTsdr_1.5M = 25 MaxTsdr_3M = 50 MaxTsdr_6M = 100 MaxTsdr_12M = 200 ; Maximum polling frequency Min_Slave_Intervall = 6 ; 0.6 ms ; I/O related keywords Modular_Station = 1 ; modular Max_Module = 152 Max_Input_Len = 20 Max_Output_Len = 12 Max_Data_Len = 32 Modul_Offset = 1 ; Parameterization related keywords Max_User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0) = 0xC0,0x00,0x00 ; Diagnostic related keywords Max_Diag_Data_Len = 80 ;Status diagnostic messages Unit_Diag_Area=16-17 Value(0) = "Status not changed" Value(1) = "Status appears" Value(2) = "Status disappears" Unit_Diag_Area_End Unit_Diag_Area=24-31 Value(0) = "Minor, recoverable" Value(16) = "Minor, unrecoverable" Value(32) = "Major, recoverable" Unit_Diag_Area_End Unit_Diag_Area=32-39 Value(16) = "Generic Error" Value(32) = "Current" Value(33) = "Current, device input side" Value(34) = "Current, inside the device" Value(35) = "Current, device output side" Value(48) = "Voltage" Value(49) = "Mains Voltage" Value(50) = "Voltage inside the device" Value(51) = "Output Voltage" Value(64) = "Temperature" Value(65) = "Ambient Temperature" Value(66) = "Device Temperature" Value(80) = "Device Hardware" Value(96) = "Device Software" Value(97) = "Internal Software" Value(98) = "User Software" Value(99) = "Data Set" Value(112) = "Additional Modules" Value(128) = "Monitoring" Value(129) = "Communication" Value(130) = "Protocol Error" Value(144) = "External Error" Value(240) = "Additional Functions" Unit_Diag_Area_End ; DPV1 related keywords DPV1_Slave = 1 Check_Cfg_Mode = 0 C1_Read_Write_supp = 1 C1_Max_Data_Len = 68 C1_Response_Timeout = 100 ;1 sec C2_Read_Write_supp = 1 C2_Max_Data_Len = 68 C2_Response_Timeout = 100 ;1 sec C2_Max_Count_Channels = 1 Max_Initiate_PDU_Length = 52 Ident_Maintenance_supp = 1 ; Definition of modules ;Modules :IN 20bytes, OUT 12bytes Module = "20bytesIN 12bytesOUT" \ 0x93,0x93,0x93,0x93,0x93,0xa3,0xa3,0xa3 1 EndModule